Constant Power Configuration Register (Cpconfig); Constant Power Configuration Register (Cpconfig) Register Field Descriptions - Texas Instruments UCD3138 Technical Reference Manual

Digital power supply controller
Hide thumbs Also See for UCD3138:
Table of Contents

Advertisement

www.ti.com

5.14.13 Constant Power Configuration Register (CPCONFIG)

Address 00020030
25
MAX_CURRENT
R/W-00 0000 0000
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 5-14. Constant Power Configuration Register (CPCONFIG) Register Field Descriptions
Bit
Field
25-16
MAX_CURRENT
15-10
Reserved
9-0
NOM_VOLTAGE
SNIU028A – February 2016 – Revised April 2016
Submit Documentation Feedback
Figure 5-14. Constant Power Configuration Register (CPCONFIG)
16
15
Type
Reset
R/W
00 0000
Configures I
0000
Max Current mode
R
00 0000
R/W
00 0000
Configures V
0000
Constant Voltage mode (Loop Oring configuration selected)
Copyright © 2016, Texas Instruments Incorporated
10
Reserved
R-00 0000
Description
setpoint used in Constant Power/Constant Current Calculations in
MAX
setpoint used in Constant Power/Constant Current Calculations in
NOM
Loop Mux Registers Reference
9
NOM_VOLTAGE
R/W-00 0000 0000
Loop Mux
0
209