6.11.26 HFO Fail Detect Register (HFOFAILDET)

Address 0x00030074
17
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 6-26. HFO Fail Detect Register (HFOFAILDET) Register Field Descriptions
Bit
Field
17-1
HFO_FAIL
_THRESH
0
HFO_DETECT
_EN
SNIU028A – February 2016 – Revised April 2016
Submit Documentation Feedback
Figure 6-30. HFO Fail Detect Register (HFOFAILDET)
HFO_FAIL_THRESH
R/W-0 0000 0000 1111 1111
Type
Reset
R/W
0 0000
Configures threshold where a clear flag is used to clear a counter in the Low
0000
Frequency Oscillator domain (if LFO counter overflows, a reset will be generated),
1111
resolution of threshold equals High Frequency Oscillator period
1111
R/W
0
Enables High Frequency Oscillator Failure Detection logic, device will be reset upon
detection of an oscillator failure
0 = Disables High Frequency Oscillator Failure Detection (Default)
1 = Enables High Frequency Oscillator Failure Detection
Copyright © 2016, Texas Instruments Incorporated
Fault Mux Registers Reference
1
Description
0
HFO_DETECT
_EN