Vsan Messages - Cisco AP775A - Nexus Converged Network Switch 5010 Reference

Nx-os system messages reference
Hide thumbs Also See for AP775A - Nexus Converged Network Switch 5010:
Table of Contents

Advertisement

VSAN Messages

S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
VSAN-2
Error Message
VSAN-3
Error Message
Error Message
Error Message
sent by addr [dec]:[dec]
VSAN-6
Error Message
Error Message
is not supported
Cisco NX-OS System Messages Reference
2-812
VSAN-2-PROGRAM_EXIT: process exiting with reason: [chars]
VSAN manager process is exiting with the reason [chars].
Explanation
Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Recommended Action
Support web site http://www.cisco.com/tac.
VSAN-3-CFS_OPERATION_FAILED: cfs [chars] operation failed : [chars]
Explanation
Cfs operation [chars1] has failed. [chars2].
Check the reason for the failure of the CFS operation and fix the problem.
Recommended Action
VSAN-3-MEM_ALLOC_FAILED: alloc failed for size:[dec]
Memory allocation of size [dec] failed.
Explanation
Do show process memory command to see memory usage of processes.
Recommended Action
VSAN-3-MESSAGE_ERROR: could not handle message:[chars] of type [dec]
Got an IPC message [chars] of type [dec1] sent by a component running on node [dec2]
Explanation
with sap [dec3].
Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Recommended Action
Support web site http://www.cisco.com/tac.
VSAN-6-ACTIVATED: VSAN:[dec] changing from suspended to active
Explanation
Making VSAN with ID [dec] active from suspended state.
No action is required.
Recommended Action
VSAN-6-CFS_MERGE_NOT_SUPPORTED: merging of fctimer configuration data
Merging of fctimer configuration data using cfs is not supported.
Explanation
No action is required.
Recommended Action
Chapter 2
System Messages and Recovery Procedures
OL-15994-03

Advertisement