Error Message
[dec]:RR-token [hex]
Error Message
Error Message
[chars]
CFS-3
Error Message
Error Message
wwn [chars], remote switch wwn [chars].Please check 'show cfs merge status name
[chars]' for more information
Error Message
OL-15994-03
CFS-2-MTS_REJECT: Verification failed reject MTS message SAP
Explanation
This MTS message could have been posted by the previous active running pre 3.x; MTS
structure has changed since then therefore ignore the MTS message, Source SAP [dec]; RR-token
[hex].
Recommended Action
No action is required.
CFS-2-PSS_ERROR: [chars]: PSS ret. val=[dec]
The CFS service has detected an error while operating on a persistent storage database.
Explanation
Recommended Action
No action is required.
CFS-2-VDC_MGR_FAIL: Failed to get a valid switch mac from VDC Manager:
Explanation
VDC manager did not respond with a proper MAC address. It could have been because
of a timeout in MTS received.
No action is required.
Recommended Action
CFS-3-ALLOCFAIL: Heap Memory allocation failed: [chars]
CFS Service is out of dynamic memory. [chars] specifies the context where the failure
Explanation
occurred.
No action is required.
Recommended Action
CFS-3-APP_MERGE_FAILED: Merge failed for app [chars], local switch
Explanation
The CFS service has detected a merge failure.
No action is required.
Recommended Action
CFS-3-CFS_PSS_CORRUPTED: [chars] PSS found corrupted
Explanation
The CFS service has detected a corrupted file in its persistent information databases
The database would be recreated.
No action is required.
Recommended Action