Cisco AP775A - Nexus Converged Network Switch 5010 Reference page 683

Nx-os system messages reference
Hide thumbs Also See for AP775A - Nexus Converged Network Switch 5010:
Table of Contents

Advertisement

Chapter 2
System Messages and Recovery Procedures
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
Error Message
SS_EID_EC_ER_IOP_STOPPED_DUE_TO_SIGNAL ) Internal error - signal caused stop
[chars]
Explanation
error.
Recommended Action
Cisco Technical Assistance Center (TAC) through the Cisco Support web site
http://www.cisco.com/tac.
Error Message
SS_EID_EC_ER_IOP_TERMINATED_ABNORMALLY ) Internal error - abnormal exit [chars]
Explanation
Recommended Action
Cisco Technical Assistance Center (TAC) through the Cisco Support web site
http://www.cisco.com/tac.
Error Message
SS_EID_EC_ER_OPEN_MSG_QUEUE_FAILED ) Internal error - message queue [chars]
Explanation
this error.
Recommended Action
node will then have to be removed and re-added back to the cluster. 2. Ensure that the software is at
the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest
level of code. 3. If the error continues, ask IBM Product Support for assistance.
Error Message
SS_EID_EC_ER_PTHREAD_CREATE_FAILED ) Internal error - threads [chars]
Explanation
error.
Recommended Action
node will then have to be removed and re-added back to the cluster. 2. Ensure that the software is at
the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest
level of code. 3. If the error continues, ask IBM Product Support for assistance.
Error Message
SS_EID_EC_ER_UNKNOWN_MESSAGE_TYPE ) Internal error - message type [chars]
Explanation
Recommended Action
Cisco Technical Assistance Center (TAC) through the Cisco Support web site
http://www.cisco.com/tac.
OL-15994-03
SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec]
The IO process stopped because of a signal received. Node was warmstarted due to this
1. Ensure that the software is at the latest level on the cluster. 2. Contact the
SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec]
The IO process exited abormally. Node was warmstarted due to this error.
1. Ensure that the software is at the latest level on the cluster. 2. Contact the
SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec]
The process was unable to open the needed message queue. Node was rebooted due to
If this error is repeated continously, 1. Re-install the code on the node. The
SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec]
The process was unable to create the needed threads. Node was rebooted due to this
If this error is repeated continously, 1. Re-install the code on the node. The
SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec]
Node was rebooted due to internal logic error.
1. Ensure that the software is at the latest level on the cluster. 2. Contact the
Cisco NX-OS System Messages Reference
SVC Messages
2-645

Advertisement

Table of Contents
loading

Table of Contents