SVC Messages
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
Error Message
) Internal error - program launch [chars]
Explanation
Recommended Action
node will then have to be removed and re-added back to the cluster. 2. Ensure that the software is at
the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest
level of code. 3. If the error continues, ask IBM Product Support for assistance.
Error Message
Internal error - fork failed [chars]
Explanation
Recommended Action
node will then have to be removed and re-added back to the cluster. 2. Ensure that the software is at
the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest
level of code. 3. If the error continues, ask IBM Product Support for assistance.
Error Message
SS_EID_EC_ER_INTERNAL_EXIT_LOGIC_ERR ) Internal error - bad exit code [chars]
Explanation
Recommended Action
Cisco Technical Assistance Center (TAC) through the Cisco Support web site
http://www.cisco.com/tac.
Error Message
SS_EID_EC_ER_INTERNAL_UNKNOWN_EXEC_MODE ) Internal error - run mode [chars]
Explanation
Recommended Action
Cisco Technical Assistance Center (TAC) through the Cisco Support web site
http://www.cisco.com/tac.
Error Message
SS_EID_EC_ER_IOP_EXITED_DUE_TO_SIGNAL ) Internal error - signal caused exit
[chars]
Explanation
due to this error.
Recommended Action
Cisco Technical Assistance Center (TAC) through the Cisco Support web site
http://www.cisco.com/tac.
Cisco NX-OS System Messages Reference
2-644
SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_EXECVE_FAILED
The process was unable to launch the IO program. Node was rebooted due to this error.
If this error is repeated continously, 1. Re-install the code on the node. The
SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_FORK_FAILED )
The process was unable to launch the IO program. Node was rebooted due to this error.
If this error is repeated continously, 1. Re-install the code on the node. The
SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec]
Node was warmstarted due to internal logic error.
1. Ensure that the software is at the latest level on the cluster. 2. Contact the
SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec]
Node was rebooted due to internal logic error.
1. Ensure that the software is at the latest level on the cluster. 2. Contact the
SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec]
The IO process exited because of a signal which was not caught. Node was warmstarted