Error Message
of [dec] seconds required for Module <[dec]> test <[chars]>
Error Message
Module <[dec]>
Error Message
monitoring test
DIAGMGR-6
Error Message
Error Message
Diagnostics

DMM-SLOT# Messages

This section contains the DMM-SLOT# messages.
OL-15994-03
DIAGMGR-5-INTRVL_INCORRECT: Monitoring Interval is less than minimum
Explanation
Health Monitoring cannot be enabled for the specified test because the interval for the
test has been incorrectly set.
The system is working properly and no action is required. If you want to
Recommended Action
specify a smaller testing interval, the error message text provides the lowest possible configurable
interval for the specified monitoring interval.
DIAGMGR-5-MODULE_MISSING: Diagnostic command issued on non-existing
A line card could not be located in a slot where a diagnostic action was requested.
Explanation
Recommended Action
Ensure the targeted line card is properly seated in the specified slot. If the line
card is properly seated, ensure the correct slot was indicated in the command-line interface. If the
line card is well-seated and the correct slot was specified, copy the error message exactly as it
appears on the screen as well as the output of show tech-support and paste the output into a separate
file. Contact your technical support representative with the gathered information.
DIAGMGR-5-NONHM_AS_HM: The Test <[chars]> cannot be used as health
Non-HM test cannot be scheduled to run as a Health Monitoring test.
Explanation
No action is required.
Recommended Action
DIAGMGR-6-BOOTUP_DIAG_OK: Module <[dec]>: Passed Online Diagnostics
The diagnostic tests did not detect any error on the card.
Explanation
This is an informational message stating that the line card passed the
Recommended Action
diagnostic tests.
DIAGMGR-6-BOOTUP_TEST_STARTED: Module <[dec]>: Running [chars]
Starting bootup testing for above module.
Explanation
No action is required.
Recommended Action