SVC Messages
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
Error Message
failure for [chars].
Error Message
[chars]
SVC-3
Error Message
SS_EID_EC_ER_ACTIVATE_CLUSTER_IP_FAILED ) Activate cluster IP failed [chars]
Error Message
Battery Failed [chars]
Cisco NX-OS System Messages Reference
2-630
SVC-2-SVC_SYSLOG_PATH_FAILURE: System health detected SVC packet path
Explanation
The CSM has been brought down by the system health monitor. The system Health has
detected a failure in the packet path between the SVC interface on the CSM and the backplane. This
The system Health test is run periodically.
Recommended Action
Issue a no shutdown on the SVC interface to bring the node back online. If a
subsequent packet path failure occurs, the CSM module should be replaced.
SVC-2-SVC_SYSLOG_URIFS_FAILURE: [chars] is unreachable for reason:
SVC interface modflash is not accessible. Modflash is the name of the file system local
Explanation
to the SVC interface, and is typically used for coredumps and temporary file transfers.
Recommended Action
Please shutdown and bring up the SVC interface in question to regain access
to the modflash file system.
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec]
The system is unable to activate the cluster IP for the config node. It will not be possible
Explanation
to execute configuration commands.
1. Shutting the interfaces of the node will force this node out of the cluster and
Recommended Action
cause another node to become the config node, which should restore the ability to execute
configuration commands. 2. If the error persists, re-install the code on the node. The node will then
have to be removed and re-added back to the cluster. 3. Ensure that the software is at the latest level
on the cluster. If not, upgrade the cluster and if necessary repeat step 2 with the latest level of code.
4. If the error continues, ask IBM Product Support for assistance.
SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_BATT_FAILURE )
The battery module on the Caching Services Module has failed. The nodes on the CSM
Explanation
will have shutdown. Other log entries may accompany this error.
Reload the Caching Services Module. If the error persists, replace the Caching
Recommended Action
Services Module.