PLATFORM Messages
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
Error Message
re-initialized successfully
Error Message
Error Message
will not be powered up (Serial number [chars])
Error Message
PLATFORM-3
Error Message
changed, [chars] Ejector is [chars], [chars] Ejector is [chars]
Error Message
were made to bring up the Module [dec], (Serial number [chars])
Cisco NX-OS System Messages Reference
2-490
PLATFORM-2-SYS_IDPROMBAD_RECOVER_PASS: Chassis IDPROM [dec] data
Explanation
Chassis IDPROM [decimal digit] invalid data was succesfully re-initialized to valid.
Enter a 'show sprom module [decimal digit] 1' to read module IDPROM
Recommended Action
contents and verify the information.
PLATFORM-2-XBAR_DETECT: Xbar [dec] detected (Serial number [chars])
Explanation
A new xbar in slot [decimal digit] is detected.
No action is required.
Recommended Action
PLATFORM-2-XBAR_PWRFAIL_EJECTORS_OPEN: Both ejectors open, Xbar [dec]
The xbar cannot be powered up because both ejectors are open.
Explanation
Enter a 'show platform internal all module [decimal digit]' and 'show module
Recommended Action
internal all module [decimal digit]' 'show sprom xbar [dec] [dec]' to read module IDPROM contents
to collect more information.
PLATFORM-2-XBAR_REMOVE: Xbar [dec] removed (Serial number [chars])
Explanation
The xbar in slot [decimal digit] has been removed.
No action is required.
Recommended Action
PLATFORM-3-EJECTOR_STAT_CHANGED: Ejectors' status in slot [dec] has
Explanation
Ejector status has changed.
Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Recommended Action
Support web site http://www.cisco.com/tac.
PLATFORM-3-MOD_BRINGUP_MULTI_LIMIT: Giving up after multiple attempts
Explanation
The module cannot be powered up even after three attempts.
Enter a 'show platform internal all module [decimal digit]' and 'show module
Recommended Action
internal all module [decimal digit]' 'show sprom xbar [dec] [dec]' to read module IDPROM contents
to collect more information.
Chapter 2
System Messages and Recovery Procedures