Svc-5 - Cisco AP775A - Nexus Converged Network Switch 5010 Reference

Nx-os system messages reference
Hide thumbs Also See for AP775A - Nexus Converged Network Switch 5010:
Table of Contents

Advertisement

SVC Messages
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
SVC-6
Error Message
) All data now unpinned [chars]
Error Message
SS_EID_CA_EV_HWS_TO_ASYNCHRONOUS ) Pinned data reduced; cache can operate normally
[chars]
Error Message
recharged [chars]
Error Message
Poweroff or power failure detected [chars]
Error Message
withdrawn [chars]
Cisco NX-OS System Messages Reference
2-652
SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_CA_EV_ALL_DATA_UNPINNED
All the customer data in the IO group is now unpinned.
Explanation
Recommended Action
Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.
SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec]
Explanation
Enough customer data has been unpinned that the cache is no longer required to operate
in write through mode because of the pinned data. (Note that the cache may still operate in write
through mode for other reasons.).
Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Recommended Action
Support web site http://www.cisco.com/tac.
SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_BATT_OK ) Battery
Battery capacity has been restoredddd to above threshold. The node will now come
Explanation
online.
Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Recommended Action
Support web site http://www.cisco.com/tac.
SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_BATT_POWER_DOWN )
The process has received a poweroff or power failure indication. The node is shutting
Explanation
down.
Restore power. If power was not removed and this occurs: 1. Reload the node.
Recommended Action
2. If the error persists, re-install the code on the line card. The node(s) will then have to be removed
and re-added back to the cluster. 3. If the error persists, replace the Caching Services Module.
SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_PWR_BUTTON ) Power
Node software was notified that AC power was being shut off or the Caching Services
Explanation
Module was being reset.
Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Recommended Action
Support web site http://www.cisco.com/tac.