Chapter 2
System Messages and Recovery Procedures
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
Error Message
checksum on module [dec] is corrupted.
Explanation
Recommended Action
Error Message
CRC checksum procedure encountered an error during initialization on module [dec],
reason:([chars]).
Explanation
Recommended Action
(mis)configurations.
Error Message
refresh procedure failed, replace the compact flash on module [dec]. Reason [dec]
Explanation
Recommended Action
Error Message
errors found [chars] test.
Explanation
Recommended Action
Error Message
requested due to errors found [chars] test.
Explanation
Recommended Action
Error Message
[dec].
Explanation
Recommended Action
OL-15994-03
SYSTEMHEALTH-2-OHMS_SUP_CF_CRC_FAILED: Compact Flash firmware CRC
Compact flash firmware has been corrupted.
Replace the compact flash on this module.
SYSTEMHEALTH-2-OHMS_SUP_CF_CRC_INIT_ERRORS: Compact Flash firmware
Compact flash CRC checksum initializations failed.
Check the compact flash on the board and any relevant system
SYSTEMHEALTH-2-OHMS_SUP_CF_REFLASH_FAILED: Compact Flash firmware
Compact flash firmware has been corrupted is corrupted.
Replace the compact flash on this module.
SYSTEMHEALTH-2-OHMS_SWITCH_RELOAD_REQ: Switch reload request due to
The system Health Switch Reload Request.
No action is required.
SYSTEMHEALTH-2-OHMS_SWITCHOVER_REQ: Supervisor switch over being
The system Health Switch Over Request.
No action is required.
SYSTEMHEALTH-2-OHMS_TCAM_PARITY_FAILED: TCAM test failed for module
TCAM test failed for module as uncorrectable parity errors were detected.
Please schedule a downtime and replace the module.