PIM6 Messages
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
Error Message
Error Message
Error Message
Error Message
PIM6-5
Error Message
Error Message
Cisco NX-OS System Messages Reference
2-468
PIM6-3-U6RIB_CONTEXT Format: Couldn't get U6RIB VRF %s
PIM6 failed to obtain unicast routing VRF from URIB.
Explanation
Parameters: Interface ...
Recommended Action
Dump core, and and and then restart component.
PIM6-3-UDP_READ Format: Error reading UDP socket
UDP Socket Error.
Explanation
Recommended Action
Dump core, and and and then restart component.
PIM6-3-UDP_SENDTO Format: udp_sendto() on %s failed: %s
Explanation
PIM6 failed to send over UDP socket.
Parameters: Message String Error String ...
Recommended Action
No action is required.
PIM6-3-WRLOCK_ASSERT Format: %s:%d: Assert, write-lock not acquired
Caller Failed to get PIM6 Shared Memory write lock
Explanation
Parameters: Function Name, Line ...
Recommended Action
No action is required.
PIM6-5-DR_CHANGE Format: DR change from %s to %s on interface %s
PIM Designated router changed on the interface.
Explanation
Parameters: Old DR address, New DR address, Interface ...
No action is required.
Recommended Action
PIM6-5-NBR_CHANGE Format: Neighbor %s %s on interface %s
PIM neighbor went up/down due to Hello-message seen/lost.
Explanation
Parameters: Neighbor IPv6 address, Neighbor state, Interface ...
No action is required.
Recommended Action