PLATFORM Messages
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
PLATFORM-1
Error Message
operating.
Error Message
Error Message
Error Message
Error Message
supplies, remove single-input configuration for optimal power usage
Error Message
insufficient power (Serial number [chars])
Cisco NX-OS System Messages Reference
2-476
PLATFORM-1-FABRIC_SWITCH_FAN_FAIL: Less than 4 required fans
Fan module has failed leaving less than 4 total fans operating. Fan needs to be replaced.
Explanation
This can lead to overheating and temperature alarms.
Enter the 'the show platform internal command
Recommended Action
rmationcommandrmationcommand' to collect more information.
PLATFORM-1-FAN_FAIL: Fan module Failed
Fan module has failed and needs to be replaced. This can lead to overheating and
Explanation
temperature alarms.
Enter the 'the show platform internal command
Recommended Action
rmationcommandrmationcommand' to collect more information.
PLATFORM-1-MDS9124_FAN_FAIL: Less than 4 required fans operating.
Explanation
Fan module has failed leaving less than 4 total fans operating. Fan needs to be replaced.
This can lead to overheating and temperature alarms.
Enter the 'the show platform internal command
Recommended Action
rmationcommandrmationcommand' to collect more information.
PLATFORM-1-PFM_ALERT: [chars]
Explanation
Platform Alert.
No action is required.
Recommended Action
PLATFORM-1-PS_SINGLE_INPUT: Both power inputs are connected for Power
Current power supply redundancy mode may not be optimal.
Explanation
Enter a 'show environment power' and 'the show platform internal command
Recommended Action
rmationcommand' to collect more information.
PLATFORM-1-XBAR_PWRDENY: Xbar [dec] can not be powered up due to
Available power in power supplies is not sufficient to power up the xbar.
Explanation
You can verify available power and current usage using the command 'show
Recommended Action
env power'. Refer to power supply document on how to increase power supply capacity.
Chapter 2
System Messages and Recovery Procedures
OL-15994-03