Error Message
[chars] is down (Isolation due to ELP failure: loopback detected)
Explanation
Recommended Action
Error Message
[chars] is down (Isolation due to ELP failure: invalid transmit B2B credit)
Explanation
Recommended Action
Error Message
[chars] is down (Isolation due to ELP failure: R_A_TOV or E_D_TOV mismatch)
Explanation
Recommended Action
Error Message
[chars] is down (Isolation due to ELP failure: revision mismatch)
Explanation
Recommended Action
Error Message
Interface [chars] is down (Isolation due to ELP failure: invalid flow control code)
Explanation
Recommended Action
Error Message
Interface [chars] is down (Isolation due to ELP failure: invalid flow control
param)
Explanation
Recommended Action
Error Message
- EPP Failure)
Explanation
Recommended Action
exchanges to determine why it failed.
OL-15994-03
PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_INVALID_TX_BBCREDIT: Interface
ELP failed on the interface due to loopback connection detected.
Connect to a port on another switch and try again.
PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_LOOPBACK_DETECTED: Interface
ELP failed on the interface due to invalid transmit B2B credit.
Configure the attached switchport correctly and try again.
PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_RATOV_EDTOV_MISMATCH: Interface
ELP failed on the interface due to R_A_TOV or E_D_TOV mismatch.
Configure R_A_TOV and E_D_TOV values correctly and try again.
PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_REVISION_MISMATCH: Interface
ELP failed on the interface due to revision mismatch.
Configure the attached switchport correctly and try again.
PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_UNKNOWN_FLOW_CTL_CODE:
ELP failed on the interface due to invalid flow control code.
Configure the attached switchport correctly and try again.
PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_UNKNOWN_FLOW_CTL_PARAM:
ELP failed on the interface due to invalid flow control param.
Configure the attached switchport correctly and try again.
PORT-5-IF_DOWN_EPP_FAILURE: Interface [chars] is down (Error Disabled
Trunk protocol failed.
'show port internal event-history msgs' will indicate the trunk protocol