DIAGMGR-3
Error Message
a Major Error Please use 'show diagnostic result <target>' to see test results
Error Message
a Minor Error Please use 'show diagnostic result <target>' to see test results
Error Message
process. Error:[chars]
DIAGMGR-4
Error Message
current slot:[dec]. Ignoring it
Error Message
is Disruptive
OL-15994-03
DIAGMGR-3-DIAG_MAJOR_DEFECT: Module <[dec]> Test <[chars]> detected
A major error was detected during diagnostic testing.
Explanation
Recommended Action
Re-seat the card and retry the test. If the same result occurs after reseating the
card and retrying the test, copy the error message exactly as it appears on the screen and gather the
output of show tech-support and any other relevant information. Contact your technical support
representative with the gathered information.
DIAGMGR-3-DIAG_MINOR_DEFECT: Module <[dec]> Test <[chars]> detected
A mior error was detected during diagnostic testing.
Explanation
Re-seat the card and retry the test. If the same result occurs after reseating the
Recommended Action
card and retrying the test, copy the error message exactly as it appears on the screen and gather the
output of show tech-support and any other relevant information. Contact your technical support
representative with the gathered information.
DIAGMGR-3-GET_CURR_SLOT_FAIL: Failed to get the current slot for the
Explanation
The process initialization has failed to get the current slot.
This is an informational message stating that a process initialization failure.
Recommended Action
DIAGMGR-4-CURR_SLOT_OFFLINE: Recevied an LC offline event for the
Explanation
The process received an offline event for the slot it is running. Ignoring it.
This is an informational message stating that an unexpected event has been
Recommended Action
encountered.
DIAGMGR-4-DISRPT_TST_START: Starting Test <[chars]> on Module <[dec]>
Starting a Disruptive Test can disturb the system's normal functionality.
Explanation
Reset target module.
Recommended Action