Cisco AP775A - Nexus Converged Network Switch 5010 Reference page 557

Nx-os system messages reference
Hide thumbs Also See for AP775A - Nexus Converged Network Switch 5010:
Table of Contents

Advertisement

Chapter 2
System Messages and Recovery Procedures
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
Error Message
[chars] is down (Isolation due to virtual IVR domain overlap)
Explanation
Recommended Action
Error Message
(Isolation due to vsan mismatch)
Explanation
configured on the remote end.
Recommended Action
Error Message
down (Isolation due to zone merge failure)
Explanation
Recommended Action
Error Message
down (Isolation due to remote zone server not responding)
Explanation
Recommended Action
Error Message
Explanation
Recommended Action
Error Message
due to failure reason: [chars] ([hex])
Explanation
Recommended Action
Error Message
([chars])
Explanation
Recommended Action
interface: show interface, show port internal informationinterface VSAN, show port internal
event-history interface VSAN.
OL-15994-03
PORT-5-IF_DOWN_VIRTUAL_IVR_DOMAIN_OVERLAP_ISOLATION: Interface
Isolated due to virtual IVR domain overlap.
No action is required.
PORT-5-IF_DOWN_VSAN_MISMATCH_ISOLATION: Interface [chars] is down
This is a trunking interface and the VSANs configured do not match with the VSANs
Check the VSANs configured on the local end with the remote end.
PORT-5-IF_DOWN_ZONE_MERGE_FAILURE_ISOLATION: Interface [chars] is
Isolated due to a failure during zone merge.
No action is required.
PORT-5-IF_DOWN_ZONE_REMOTE_NO_RESP_ISOLATION: Interface [chars] is
Isolated due to remote zone server not responding.
No action is required.
PORT-5-IF_PORT_GUARD_DOWN: Interface [chars] is down ([chars])
The interface is down due to the port guard configuration.
Perform a shut followed by a no shut to bring up the interface.
PORT-5-IF_PORT_QUIESCE_FAILED: Interface [chars] port quiesce failed
There may be few packet drops due to this failure.
No action is required.
PORT-5-IF_TRUNK_DOWN: Interface [chars], vsan [chars] is down
The interface [chars] is trunking, VSAN [chars] is down with the reason in ().
The following commands will help determine why this VSAN is down on this
Cisco NX-OS System Messages Reference