Chapter 2
System Messages and Recovery Procedures
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - f e e d b a c k - d o c @ c i s c o . c o m
Error Message
alarm. Sensor=[dec] Temperature=[dec] MajThreshold=[dec]
Explanation
Recommended Action
Error Message
Sensor=[dec] Temperature=[dec] MinThreshold=[dec]
Explanation
Recommended Action
Error Message
alarm. Sensor=[dec] Temperature=[dec] MinThreshold=[dec]
Explanation
Recommended Action
Error Message
alarm. Minor temperature alarm pending. Sensor=[dec] Temperature=[dec]
MajThreshold=[dec] MinThresh=[dec]
Explanation
threshold still exceeded.
Recommended Action
Error Message
Explanation
Recommended Action
Error Message
connection fault caused bus switchover(BUS_A to BUS_B)
Explanation
Recommended Action
Error Message
connection or device fault caused bus switchover(BUS_A to BUS_B)
Explanation
Recommended Action
OL-15994-03
PLATFORM-2-MOD_TEMPMAJOR_OK: [chars] recovered from major temperature
Module in slot [decimal digit] major temperature threshold.
Enter a 'show env temperature' to collect more information.
PLATFORM-2-MOD_TEMPMINALRM: [chars] reported minor temperature alarm.
Module in slot [decimal digit] has exceeded mior temperature threshold.
Enter a 'show env temperature' to collect more information.
PLATFORM-2-MOD_TEMPOK: [chars] recovered from minor temperature
Module in slot [decimal digit] mior temperature threshold.
Enter a 'show env temperature' to collect more information.
PLATFORM-2-MOD_TEMPRECOVER: [chars] recovered from major temperature
Module in slot [decimal digit] recovered from major temperature threshold. Minor
Enter a 'show env temperature' to collect more information.
PLATFORM-2-PFM_CRITICAL: [chars]
Platform Critical.
No action is required.
PLATFORM-2-PFM_FATW_BUS_SWITCH: Backplane two wire [chars] bus
Could not access some modules using BUS_A, but can access using BUS_B.
Enter a 'show platform internal error'.
PLATFORM-2-PFM_FATW_BUS_SWITCH: Backplane two wire [chars] bus
Could not access some modules using BUS_A, but can access using BUS_B.
Enter a 'show platform internal error'.