CHAPTER 21 CAN CONTROLLER

Completing Reception

RCx of the reception complete register (RCR) becomes 1 after storing the received message.
If a reception interrupt is enabled (RIEx of the reception interrupt enable register (RIER) is 1), an interrupt
occurs.
Note:
This CAN controller will not receive any messages transmitted by itself.