CHAPTER 6 CLOCK SUPERVISOR
Bit name
bit7
SCKS
Sub clock select
bit6
MM
Main clock
missing
bit5
SM
Sub clock
missing
bit4
RCE
CR oscillation
clock enable
bit3
MSVE
Main clock
supervisor
enable
bit2
SSVE
Sub clock
supervisor
enable
bit1
SRST
Sub-clock mode
reset
bit0
Reserved bit
114
This bit permits built-in CR oscillation clock to be used as a sub-clock. Only "S" suffix
product is valid to this function.
"1": It is possible to change to the sub clock mode with built-in CR oscillation clock.
"0": It is not possible to change to the sub clock mode.
This bit is initialized to "0" by power-on reset, external reset, or low voltage detection
reset in "T" suffix product. It is initialized to "0" by power-on reset or external reset
without "T" suffix product.
It is necessary to set this bit to "1" in the main clock mode before the sub-clock
supervisor after the above-mentioned is initialized operates automatically.
Moreover, after setting to "1", this bit cannot be reset to "0" by software.
This bit indicates the oscillation missing of main clock terminal X0 and X1 was detected.
"1": Missing main clock has been detected.
"0": Missing main clock has not been detected.
This bit is initialized to "0" by power-on reset, external reset, or low voltage detection
reset with "T" suffix product.
It is initialized to "0" by power-on reset or external reset without "T" suffix product.
This bit indicates the oscillation missing of sub clock terminal X0A and X1A was
detected. No "S" suffix product is valid to this function.
"1": Missing sub-clock has been detected.
"0": Missing sub-clock has not been detected.
This bit is initialized to "0" by power-on reset, external reset, or low voltage detection
reset with "T" suffix product.
It is initialized to "0" by power-on reset or external reset without "T" suffix product.
This bit permits built-in CR oscillation.
"1": Built-in CR oscillation is enabled.
"0": Built-in CR oscillation is disabled.
This bit is initialized to "1" by power-on reset, external reset, or low voltage detection
reset with "T" suffix product.
It is initialized to "1" by power-on reset or external reset without "T" suffix product.
Please set this bit in "1" after confirming both the following:
- The supervisor of main and sub-clock is disabled.
- MM and SM bits are "0".
This bit permits monitoring for main clock oscillation.
"1": Main clock supervisor is enabled.
"0": Main clock supervisor is disabled.
This bit is initialized to "1" by power-on reset or low voltage detection reset with "T"
suffix product.
It is initialized to "1" by power-on reset or external reset without "T" suffix product.
This bit permits monitoring for sub clock oscillation.
"1": Sub clock supervisor is enabled.
"0": Sub clock supervisor is disabled.
This bit is initialized to "1" by power-on reset or low voltage detection reset with "T"
suffix product.
It is initialized to "1" by power-on reset or external reset without "T" suffix product.
This bit permits the reset output when transmitting from main clock/PLL clock mode to
the sub-mode with sub-clock breakdown.
"1": Output reset.
"0": Not output reset
This bit is initialized to "0" by power-on reset, external reset, or low voltage detection
reset with "T" suffix product.
It is initialized to "0" by power-on reset or external reset without "T" suffix product.
This bit is reserved.
Be sure to write "0" to this bit.
Read value is always "0".
Function