Remote Request Receiving Register (RRTRR)

After a remote frame is stored in the message buffer (x), RRTRx becomes 1 (at the same
time as RCx setting to 1).
Register Configuration
Figure 21.4-18 Configuration of the Remote Request Receiving Register (RRTRR)
Address
CAN1:
00008B
Address
CAN1:
00008A
R/W : Read/Write
Register Function
Conditions for RRTRx = 0
• Write 0 to RRTRx.
• After a received data frame is stored in the message buffer (x) (at the same time as RCx setting to 1).
• Transmission by the message buffer (x) is completed (TCx of the transmission complete register (TCR)
is 1).
Writing 1 to RRTRx is ignored.
1 is read when a Read Modify Write instruction is performed.
Note:
If setting to 1 by completion of the receive operation and clearing to 0 by writing occur at the same
time, the bit is set to 1.
474
bit15
bit14
bit13
RRTR15
RRTR14
RRTR13
H
R/W
R/W
R/W
bit7
bit6
bit5
RRTR7
RRTR6
RRTR5
H
R/W
R/W
R/W
bit12
bit11
bit10
RRTR12
RRTR11
RRTR10
R/W
R/W
R/W
bit4
bit3
bit2
RRTR4
RRTR3
RRTR2
RRTR1
R/W
R/W
R/W
bit9
bit8
RRTRR1(Upper)
RRTR9
RRTR8
Reset value
0 0 0 0 0 0 0 0
R/W
R/W
bit1
bit0
RRTRR1(Lower)
RRTR0
Reset value
0 0 0 0 0 0 0 0