Rep 91.27 Cleaning Unit Motor Assembly And Home Sensor - Xerox ColorQube 9303 Series Service Manual

Table of Contents

Advertisement

6.
Remove slide drawer assembly,
Figure
1
Extend the drawer slide to align
apertures with screw heads.
Figure 2 drawer slide removal
Replacement
1.
Replacement is the reverse of the removal procedure.
2.
Take care not to insert any twists into the cable, refer to
Repairs/Adjustments
REP 91.26, REP 91.27
2.
2
Remove 3 screws then remove the
drawer slide.
Figure 1
for correct cable route.
REP 91.27 Cleaning Unit Motor Assembly and Home
Sensor
Parts List on
PL 94.10
Removal
Switch off the electricity to the machine. Refer to
from the customer supply while performing tasks that do not need electricity. Electricity
can cause death or injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Remove the rear covers,
2.
Remove the rear drum fan shroud,
3.
Lower the power supply. Removing the 4 screws that restrain the power supply. Lift the
power supply so the supporting hooks are no longer seated then lower the power supply
onto the machine base. It is not necessary to disconnect the power supply wiring for this
procedure.
4.
Remove the cleaning unit motor assembly,
Figure 1 Motor assembly removal
February 2013
4-364
WARNING
GP
14. Disconnect the power cord
WARNING
PL 81.10 Item
1.
PL 94.20 Item
5.
Figure
1.
2
Disconnect the harnesses,
then remove the motor
assembly.
ColorQube® 9303 Family
1
Remove 2 screws.

Advertisement