Rep 91.30 Drum Position Encoder Assembly - Xerox ColorQube 9303 Series Service Manual

Table of Contents

Advertisement

REP 91.30 Drum Position Encoder Assembly

Parts List on
PL 94.20
Removal
Switch off the electricity to the machine. Refer to
from the customer supply while performing tasks that do not need electricity. Electricity
can cause death or injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
1.
Open front door.
2.
Remove the inner cover,
PL 81.11 Item
3.
Remove the front drum shroud,
PL 94.20 Item
Do not remove gold coloured screws from the encoder.
4.
Remove the drum position encoder,
A
2
1
Remove the ground plate
Disconnect harnesses.
and centre screw, A.
Figure 1 Encoder removal
ColorQube® 9303 Family
WARNING
GP
14. Disconnect the power cord
WARNING
2.
7.
CAUTION
Figure
1.
4
Pull encoder away
from the drum. Feed
the harness through
the centre of the
encoder.
3
Remove 3 silver coloured
screws. See CAUTION.
Do not remove gold coloured
screws.
Replacement
1.
Replacement is the reverse of the removal procedure.
2.
Orientate the encoder as shown in
encoder and align the drum heater bar with the centre opening.
3.
Rotate the encoder until the screw holes line up and then press it on fully in this orienta-
tion.
4.
Replace the lower and upper left screws. Replace the grounding plate, along with the cen-
tre and upper right screws.
5.
Reconnect the harness.
6.
Ensure the wiring is not pinched when replacing the ground plate and screw,
7.
Run the relevant diagnostic routines, refer to
February 2013
4-373
Figure
2. Feed the harness through the centre of the
Figure 2 Encoder replacement
GP 37
Post Part Replacement Routines.
Figure
1.
Repairs/Adjustments
REP 91.30