Xerox ColorQube 9303 Series Service Manual page 37

Table of Contents

Advertisement

-50V Short Circuit Check
Procedure
Switch off the machine,
GP
14.
Refer to
WD
1.4. Disconnect PJDC1 from the
between pin 18 of the disconnected PJ and the chassis. The circuit is good.
Y
N
Go to
01K
and follow the procedure for the
Go to
01K
and follow the procedure for the
The fault is still active.
Y
N
Perform
SCP 5
Final Actions.
Install a new power supply unit,
PL 1.15 Item
Power supply unit
Figure 1 Component location
ColorQube® 9303 Family
power supply unit
and check for a short circuit
IME controller
PWB.
Quad wave amp PWB.
2.
Red LED
01-535-00 Power Interlock Failed: No Heater Requests RAP
01-535-00 The IME power interlock has failed because the AC power manager heater requests
are not being updated.
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
death or injury. Moving parts can cause injury.
Switch off the machine, then switch on the machine,
Go to
WD 9.3
and check the front door interlock switch (S01-103) and PJ801. The voltage at
PJ801 pin 4 on the
drum driver PWB
actuated/deactuated.
Y
N
Refer to
GP
13, How to Check a Switch. Check the wiring between the interlock switch
and PJ801 and repair the wiring as necessary, refer to
components:
Front door interlock switch, (S01-103),
Drum driver PWB,
PL 1.15 Item
Go to 01A, AC Power Distribution RAP and check for the correct AC supply. If necessary,
install a new power supply unit,
February 2013
2-13
WARNING
GP
14. Disconnect the power cord. Electricity can cause
GP
14.
changes when the front door interlock switch is
REP
1.1. If necessary, install new
PL 1.15 Item
7.
4.
PL 1.15 Item
2.
Status Indicator RAPs
01-530-00, 01-535-00

Advertisement

Table of Contents
loading

Table of Contents