Workspace
Observe the following when placing Prodigy Plus in its operating
location:
•
Prodigy Plus has an approximate weight of 128 kg (282
lbs.) and requires a table capable of safely supporting 300
lbs.
•
System Dimensions:
864 x 686 x 1041 mm (34 x 27 x 41 in)
Four-inch minimum space behind unit for air circulation
•
Dedicated outlet requirements:
110-120 VAC, 60 Hz, 15 A min. (20 amp recommended)
–or–
220-240 VAC, 50/60 Hz, 7 A min. (10 amp recommended)
•
Temperature: 18–32°C (65-90°F)
•
Relative Humidity: 30-80%, Non-condensing
•
Ethernet 10/100 Base T network
•
Network patch cable with RJ45 connectors
•
Optional UPS for power interruptions (brown-out
conditions):
Rated Power – 2200 VA
Output Power – 1600 watts