Z Drive Belt - Stratasys F120 User Manual

Shared office 3d printer
Hide thumbs Also See for F120:
Table of Contents

Advertisement

Customer Replaceable Units

Z Drive Belt

Required Tools
3 mm hex wrench
Small flat head screwdriver
Removing the Z Drive Belt
1. Power OFF the Printer. See
2. Remove the top cover. See
3. From inside the gantry enclosure, Use a 3 mm hex wrench to loosen the Z motor mounting
screws (4). See
4. Using a small flat head screwdriver, relax the belt tension by gently prying the Z motor
tension bracket away from the compression spring. See
5. While the belt tension is relaxed, remove the Z drive belt from its pulleys and extract it from
the printer.
"Powering Off" (page
"Removing the Top Cover" (page
Figure
32.
Figure 32: Z Motor Mounting Screw Locations
Figure 33: Relaxing Z Belt Tension
© Copyright 2020 Stratasys. All rights reserved.
159).
166).
Figure
33.
Z Drive Belt
Page 179