ADTRAN 1000R Series Command Reference Manual page 567

Adtran network device manual
Hide thumbs Also See for 1000R Series:
Table of Contents

Advertisement

Command Reference Guide
bonding txadd-timer <seconds>
Use the bonding txadd-timer command to specify the value (in seconds) for the aggregate call connect
timeout. Use the no form of this command to return to the default value.
Syntax Description
<seconds>
Default Values
By default, the bonding txadd-timer value is 50 seconds.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, and 4000 Series units.
Command History
Release 1.1
Functional Notes
Specifies the length of time both endpoints wait for additional calls to be connected at the end of
negotiation before deciding that the bonding call has failed. The factory default setting is sufficient for most
calls to connect, although when dialing overseas it may be necessary to lengthen this timer to allow for
slower call routing.
Usage Examples
The following example defines a bonding txadd-timer value of 95 seconds:
(config)#interface bri 1/2
(config-bri 1/2)#bonding txadd-timer 95
61200510L1-35E
Specifies the number of seconds the endpoint will wait for additional channels (to
add to the bonded aggregate) before considering the bonding negotiation a
failure.
Command was introduced.