ADTRAN 1000R Series Command Reference Manual page 681

Adtran network device manual
Hide thumbs Also See for 1000R Series:
Table of Contents

Advertisement

Command Reference Guide
Serial Interface Configuration Command Set
invert txclock
Use the invert txclock command to configure the serial interface to invert the transmit clock (found in the
transmitted data stream) before sending the signal. Use the no form of this command to return to the
default value.
Syntax Description
No subcommands.
Default Values
By default, the serial interface does not invert transmit clock (txclock).
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, and 4000 Series and Total Access 900 Series units.
Command History
Release 1.1
Command was introduced.
Functional Notes
If the serial interface cable is long, causing a phase shift in the data, the transmit clock can be inverted
(using the invert txclock command). This switches the phase of the clock, which compensates for a long
cable. If the transmit clock of the connected device is inverted, use the invert rxclock command to
configure the receiving interface appropriately.
Usage Examples
The following example configures the serial interface to invert the transmit clock:
(config)#interface serial 1/1
(config-ser 1/1)#invert txclock
61200510L1-35E
Copyright © 2005 ADTRAN
681

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF