Command Reference Guide
frame-relay lmi-n393dce <counter>
Use the frame-relay lmi-n393dce to set the N393 LMI monitored event counter for the DCE endpoint.
Typical applications should leave the default value for this counter. Use the no form of this command to
return to the default value.
Syntax Description
<counter>
Default Values
By default, the LMI monitored event counter for the DCE endpoint is set to four events.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 and Total Access 900 Series units.
Command History
Release 1.1
Usage Examples
The following example sets the N393 threshold for five events:
(config)#interface frame-relay 1
(config-fr 1)#frame-relay lmi-n393dce 5
61200510L1-35E
Sets the counter value (valid range: 1 to 10).
Command was introduced.
Copyright © 2005 ADTRAN
Frame Relay Interface Config Command Set
852