SHDSL Interface Configuration Command Set
loopback remote inband
Use the loopback remote inband command to inject the selected inband loop-up pattern into the data
stream to cause a loopback at the far end. Use the no form of this command to inject a loop-down pattern
into the data stream to cause an existing inband loopback at the far end to cease.
Syntax Description
No subcommands.
Default Values
By default, this command is enabled.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, and 4000 Series units.
Command History
Release 4.1
Command was introduced.
Usage Examples
The following example injects a loop-down pattern into the data stream, causing existing loopbacks at the
far end to stop:
(config)#interface shdsl 1/1
(config-shdsl 1/1)#no loopback remote inband