Command Reference Guide
Frame Relay Sub-Interface Config Command Set
dial-backup auto-backup
Use the dial-backup auto-backup command to configure the Frame Relay sub-interface to automatically
attempt a dial-backup upon failure. For more detailed information on Frame Relay dial-backup
functionality, refer to the Functional Notes and Technology Review sections of dial-backup call-mode
[answer | answer-always | originate | originate-answer | originate-answer-always]
on page
876.
Syntax Description
No subcommands.
Default Values
By default, all backup endpoints will automatically attempt dial-backup upon a failure.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 Series units.
Command History
Release 1.1
Command was introduced.
Usage Examples
The following example enables automatic dial-backup on the endpoint:
(config)#interface frame-relay 1.16
(config-fr 1.16)#dial-backup auto-backup