21.3.1
Clock Timing
Table 21.4 Clock Timing
Conditions: V
= 4.5 V to 5.5 V, AV
CC
V
= AV
SS
T
= –40°C to +85°C (wide-range specifications)
a
Item
Clock cycle time
Clock high pulse width
Clock low pulse width
Clock rising time
Clock falling time
Oscillation settling time after
reset (crystal)
Oscillation settling time after
leaving software standby mode
(crystal)
External clock output delay
settling time
External clock input low pulse
width
External clock input high pulse
width
External clock rising time
External clock falling time
= 4.5 V to 5.5 V, AV
CC0
= 0 V, Iφ = 8 to 40 MHz, Pφ = 8 to 35 MHz,
SS
Symbol
t
cyc
t
CH
t
CL
t
Cr
t
Cf
t
OSC1
t
OSC2
t
DEXT
T
EXL
T
EXH
T
EXr
T
EXf
t
CH
Iφ
Figure 21.2 System Bus Clock Timing
Section 21 Electrical Characteristics
= 4.5 V to 5.5 V,
CC1
Min.
Max.
25
125
5
5
5
5
20
10
2
45
45
5
5
t
cyc
t
Cf
t
t
CL
Cr
Rev. 3.00 Mar. 14, 2006 Page 765 of 804
Unit.
Test Conditions
ns
Figure 21.2
ns
ns
ns
ns
ms
Figure 21.4
ms
Figure 21.3
ms
Figure 21.4
ns
Figure 21.5
ns
External clock
input frequency =
4 to 9 MHz
ns
ns