4.6.4

Standby

General
SCALANCE X switches support not only ring redundancy within a ring but also redundant
linking of rings or open network segments (linear bus). In the redundant link, rings are
connected together over Ethernet connections. This is achieved by configuring a master/slave
device pair in one ring so that the devices monitor each other and, in the event of a fault,
redirect the data traffic from the normally used master Ethernet connection to the substitute
(slave) Ethernet connection.
Standby redundancy
S7-300
Industrial Ethernet / PROFINET (Twisted Pair)
Industrial Ethernet / PROFINET (Fiber Optic)
S7-1500
S7-400
Figure 4-3
Example of a redundant link between rings
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 05/2017, C79000-G8976-C248-12
Operator Station
SCALANCE
XM408-8C
100 Mbit/s
SCALANCE X208
SCALANCE XB205-3
as standby master
100 Mbit/s
SCALANCE
X204-2
4.6 Redundancy mechanism
Operator Stations
SCALANCE
XR528-6M
S7-1500
SCALANCE XB205-3
as standby slave
SCALANCE
X308-2
SIMATIC
S7-1200
Technical basics
IPC