● Broadcast
Number of received broadcast frames.
● CRC
Number of frames with a bad CRC checksum.
● Undersize
Number of frames that are shorter than 64 bytes.
● Oversize
Number of frames discarded because they were too long.
● Fragments
Number of frames that are shorter than 64 bytes and have a bad CRC checksum.
● Jabbers
Number of frames with a VLAN tag that have a bad CRC checksum and will be discarded
because they are too long.
● Collisions
Number of collisions of received frames.
● Utilization [%]
Utilization of the port during a sample.
5.3.9

Unicast

Status of the unicast filter table
This page shows the current content of the unicast filter table. This table lists the source
addresses of unicast address frames. Entries can be made either dynamically when a node
sends a frame to a port or statically by the user setting parameters.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 05/2017, C79000-G8976-C248-12
Configuring with Web Based Management
5.3 The "Information" menu