Chapter 8 Option CardsC2000-HS

8-2 EMC-D42A

-- Extension card for 4-point digital input / 2-point digital input
I/O Extension
Card
MO10–MO11

8-3 EMC-D611A

-- Extension card for 6-point digital input (110V
I/O Extension
Card

8-4 EMC-R6AA

-- Relay output extension card (6-point N.O. output contact)
Relay Extension
RA10–RA15
Card
RC10–RC15
Terminals
Common for Multi-function input terminals
COM
Select SINK (NPN) / SOURCE (PNP) in J1 jumper / external power
supply
Refer to Pr. 02-26–Pr. 02-29 to program the multi-function inputs
MI10–MI13.
Internal power is applied from terminal E24: +24V
5W
MI10–MI13
External power +24V
30W
ON: the activation current is 6.5mA
OFF: leakage current tolerance is 10μA
Multi-function output terminals (photocoupler)
The AC motor drive releases various monitor signals, such as drive
in operation, frequency attained and overload indication, via
transistor (open collector).
Common for multi-function output terminals MO10, MO11
MXM
(photocoupler)
Max 48V
Terminals
AC
AC power Common for multi-function input terminal (Neutral)
Refer to Pr. 02-26–Pr. 02-31 for multi-function input selection
Input voltage: 100–130V
Input frequency: 47–63Hz
MI10–MI15
Input impedance: 27Kohm
Terminal response time:
ON: 10ms
OFF: 20ms
Terminals
Refer to Pr. 02-36–Pr. 02-41 for multi-function output selection
Resistive load:
3A (N.O.) / 250V
5A (N.O.) / 30V
Inductive load (COS 0.4)
1.2A (N.O.) / 250V
2.0A (N.O.) / 30V
It is used to output each monitor signal, such as drive is in
operation, frequency attained or overload indication.
Descriptions
: max. voltage 30V
DC
MO10
MO11
MXM
50mA
DC
input voltage)
AC
Descriptions
AC
Descriptions
AC
DC
AC
DC
8-14
±5% 200mA,
DC
, min. voltage 19V
DC
DC
,