Fuji Electric FRENIC-HVAC User Manual page 40

Frenic-hvac series
Hide thumbs Also See for FRENIC-HVAC:
Table of Contents

Advertisement

(060to 300HP)
Item
Type
(FRN_ _ _AR1-5U) (*1)
Nominal
Three
AC575V
applied motor
phase
motor
[HP] (*2)
input
(Rated output)
Single
phase
input
Three
Rated capacity (kVA)
phase
(*3)
input
Rated current (A)
Single
Rated capacity (kVA)
phase
(*3)
input
Rated current (A)
Rated voltage (V) (*4)
Three-phase, 575 to 600 V (with AVR function)
Overload capability
110%-1 min (Overload interval: Compliant with IEC 61800-2)
Three
Main power supply
phase
(number of phases,
Three-phase, 575 to 600 V, 50/60 Hz
input
voltage, frequency)
Rated current (A)
(*5)
Required power
supply capacity
[kVA]
Main power supply
(number of phases,
Single-phase, 575 to 600 V, 50/60 Hz
voltage, frequency)
Single
phase
Rated current [A] (*5)
input
Required power
supply capacity
[kVA]
Auxiliary control power
supply:
Single-phase, 575 to 600 V, 50/60 Hz
(number of phases, voltage,
frequency)
Auxiliary main power supply
Single-phase, 575 to 600 V, 50/60 Hz
(number of phases, voltage,
frequency) (*6)
Voltage: +10 to -15% (Interphase voltage unbalance : 2% or less) (*9),
Voltage, frequency variations
Frequency: +5 to -5%
Braking torque [%] (*7)
10 to 15
DC injection braking
Braking start frequency: 0.0 to 60.0 Hz; Braking time: 0.0 to 30.0 s;
Braking operation level: 0 to 60%
EMC standards compliance : Category C3 (emission) / 2nd Env.
EMC filter (IEC/EN 61800-3) (*8)
(Immunity)
Built-in (IEC/EN 61000-3-2(*10),
DC reactor (DCR) (*8)
Fundamental
Power factor
> 0.98
wave power factor
(at the rated
load)
Total power factor ≥ 0.90
Efficiency (at the rated load) (%)
Applicable (safety) standards
UL 508C, C22.2 No. 14, IEC/EN 61800-5-1
Enclosure
NEMA/UL 50
NEMA/UL Type 1, NEMA/UL Type 12(*11)
Cooling method
Fan cooling
Weight / Mass
NEMA/UL Type 1
[lbs]
NEMA/UL Type 12
UL open type
-
Site location
UL open type /
NEMA/
14 to 122°F
Ambient
UL Type 1
temperature
NEMA/
14 to 104°F
UL Type 12
Relative humidity
Atmosphere
Altitude
Atmospheric pressure
Vibration
Specifications
060
075
100
125
60
75
100
125
20
25
30
40
62
76
103
124
63
77
104
125
24
29
40
48
24.5
30.0
40.5
48.7
57.9
71.0
94.7
113
58
71
95
113
57.9
71.0
94.7
113
34
41
55
65
IEC/EN 61000-3-12)
98
98
98
98
110
110
154
154
110
110
154
154
Indoors
5 to 95% (No condensation)
The inverter must not be exposed to dust, direct sunlight, corrosive gases,
flammable gases, oil mist, vapor or water drops. Pollution degree 2
(IEC/EN 60664-1) (*12)
The atmosphere can contain a small amount of salt. (0.01 mg/cm
per year)
The inverter must not be subjected to sudden changes in temperature
that will cause condensation to form.
3,300 ft max. (*13)
86 to 106 kPa
3mm
2 to less than 9 Hz
2
10 m/s
9 to less than 200 Hz
2-7
150
200
250
300
150
200
250
300
50
75
100
100
145
210
260
287
146
211
262
289
56
81
101
111
56.9
82.2
102
112
140
199
249
272
140
199
248
271
140
199
249
272
81
115
144
157
Standard accessory
(IEC/EN 61000-3-12)
98
98
98
98
UL open type
154
154
207
216
216
2
or less
2.1 Standard Model