H codes: High Performance Functions
Code
Name
H03
Data Initialization
H04
Auto-reset
H05
(Reset interval) 0.5 to 60.0 s
H06
Cooling Fan ON/OFF Control
H07
Acceleration/Deceleration Pattern
H08
Rotational Direction Limitation
H09
Starting Mode
H11
Deceleration Mode
H12
Instantaneous Overcurrent Limiting
(Mode selection)
H13
Restart Mode after Momentary Power
Failure
H14
(Frequency fall rate) Inherit: With the selected deceleration time
H15
(Continuous running level) 200 to 300 Vdc (230 V class series)
H16
(Allowable momentary power
H26
Thermistor (for motor)
(Mode selection)
H27
H30
Communications Link Function
(Mode selection)
H42
Capacitance of DC Link Bus Capacitor
H43
Cumulative Run Time of Cooling Fan
H44
Startup Counter for Motor 1
H45
Mock Alarm
H46
Starting Mode
(Auto search delay time 2)
H47
Initial Capacitance of DC Link Bus
Capacitor
H48
Cumulative Run Time of Capacitors on
Printed Circuit Boards
H49
Starting Mode
(Auto search delay time 1)
*1 The factory default differs depending upon the inverter's capacity. See Table A.
*4 The motor parameters are set by capacities. See Table B.
0: Disable initialization
1: Initialize all function code data to factory defaults
2: Initialize motor 1 parameters
10: Initialize real-time clock information
11: Initialize function code data except communication function
codes
12: Initialize U code data (Customizable logic function codes)
71: Initialize according to application (Compressor)
72: Initialize according to application (Fan)
73: Initialize according to application (Single pump)
(Times) OFF: Disable; 1 to 20
0: Disable (Always in operation)
1: Enable (ON/OFF controllable)
0: Linear
1: S-curve (Weak)
2: S-curve (Strong)
3: Curvilinear
0: Disable
1: Enable (Reverse rotation inhibited)
2: Enable (Forward rotation inhibited)
3: Enable (Reverse rotation inhibited, setting only)
4: Enable (Forward rotation inhibited, setting only)
(Auto search) 0: Disable
1: Enable (At restart after momentary power failure)
2: Enable (At restart after momentary power failure and at
normal start)
0: Normal deceleration
1: Coast-to-stop
0: Disable
1: Enable
0.1 to 20.0 s
(Restart time)
0.01 to 100.00 Hz/s
Auto: With the current limiter
400 to 600 Vdc (460 V class series)
575 to 863 Vdc (575 V class series)
Auto: Automatically determined by inverter
failure time)
0.0 to 30.0 s
0: Disable
1: PTC (The inverter immediately trips with OH4 displayed.)
2: PTC (The inverter issues output signal THM and continues to
run.)
(Level) 0.00 to 5.00 V
Frequency command
0: F01/C30
1: RS-485 (Port 1)
2: F01/C30
3: RS-485 (Port 1)
4: RS-485 (Port 2)
5: RS-485 (Port 2)
6: F01/C30
7: RS-485 (Port 1)
8: RS-485 (Port 2)
Meas (Measure initial value), Failed (Measurement failed),
2 to 65535
Indication for replacement of DC link bus capacitor
Indication for replacement of cooling fan
0 to 99990 (in units of 10 hours)
Indication of cumulative startup count
0 to 65535
0: Disable
1: Enable (Once a mock alarm occurs, the data automatically
returns to 0.)
0.1 to 20.0 s
Meas (Measure initial value), Failed (Measurement failed),
2 to 65535
Indication for replacement of DC link bus capacitor
Indication for replacement of capacitors
0 to 99990 (in units of 10 hours)
0.0 to 10.0 s
Data setting range
Run command
F02
F02
RS-485 (Port 1)
RS-485 (Port 1)
F02
RS-485 (Port 1)
RS-485 (Port 2)
RS-485 (Port 2)
RS-485 (Port 2)
6-12
Change
Data
Default
Related
when
copying
setting
page
running
N
N
0
6-141
Y
Y
OFF
6-146
Y
Y
5.0
Y
Y
1
6-148
Y
Y
0
N
Y
0
N
Y
0
Y
Y
0
6-151
Y
Y
1
Y
Y1
*1
Y
Y
Auto
Y
Y1
235
470
674
Y
Y
Auto
Y
Y
0
Y
Y
0.35
Y
Y
0
6-153
Y
N
-
6-155
Y
N
-
Y
N
-
6-158
Y
N
0
6-159
Y
Y1
*4
Y
N
-
Y
N
-
Y
Y
0.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents