C codes: Control Functions of Frequency
Code
Name
C01
Jump Frequency 1
C02
2
C03
3
C04
(Hysteresis width) 0.0 to 30.0 Hz
C05
Multistep Frequency 1
C06
2
C07
3
C08
4
C09
5
C10
6
C11
7
C12
8
C13
9
C14
10
C15
11
C16
12
C17
13
C18
14
C19
15
C21
Pattern Operation
(Mode selection) 0: Carry out a single cycle of the specified pattern operation and
C22
Pattern Operation
C23
C24
C25
C26
C27
C28
C30
Frequency Command 2
C31
Analog Input Adjustment for [12]
C32
C33
(Filter time constant) 0.00 to 5.00 s
C34
(Gain base point) 0.00% to 100.00%
C35
C36
Analog Input Adjustment for [C1]
C37
C38
(Filter time constant) 0.00 to 5.00s
C39
(Gain base point) 0.00% to 100.00%
C40
Terminal [C1] Input Range Selection
C41
Analog Input Adjustment for [V2]
C42
C43
(Filter time constant) 0.00 to 5.00 s
C44
(Gain base point) 0.00% to 100.00%
C45
C53
Selection of Normal/Inverse Operation
(Frequency command 1)
C55
Analog Input Adjustment for Terminal [12]
C56
(Bias base point) 0.00 to 100.00%
0.0 to 120.0 Hz
0.00 to 120.00 Hz
stop the inverter output
1: Carry out the specified pattern operation repeatedly and stop
the inverter output upon receipt of a stop command.
2: Carry out a single cycle of the specified pattern operation and
continue to run at the last reference frequency.
(Stage 1) 0.00 to 6000.00 s
FWD/RED 1 to 4
(Stage 2)
(Stage 3)
(Stage 4)
(Stage 5)
(Stage 6)
(Stage 7)
0: Enable
/
keys on the keypad
1: Voltage input to terminal [12] (-10 to +10 VDC)
2: Current input to terminal [C1] (4 to 20 mA DC)
3: Sum of voltage and current inputs to terminals [12]
and [C1]
5: Voltage input to terminal [V2] (0 to 10 VDC)
7: Terminal command UP/DOWN control
8: Enable
/
keys on the keypad
(balanceless-bumpless switching available)
10: Pattern operation
-5.0% to 5.0%
(Offset)
(Gain) 0.00% to 200.00%
(Polarity) 0: Bipolar 1: Unipolar
-5.0% to 5.0%
(Offset)
(Gain) 0.00% to 200.00%
0: 4 to 20 mA
1: 0 to 20 mA
-5.0% to 5.0%
(Offset)
(Gain) 0.00% to 200.00%
(Polarity) 0: Bipolar 1: Unipolar
0: Normal operation
1: Inverse operation
-100.00 to 100.00%
(Bias value)
Data setting range
6-10
Change
Data
Default
Related
when
copying
setting
page
running
Y
Y
0.0
6-125
Y
Y
0.0
Y
Y
0.0
Y
Y
3.0
Y
Y
0.00
Y
Y
0.00
Y
Y
0.00
Y
Y
0.00
Y
Y
0.00
Y
Y
0.00
Y
Y
0.00
Y
Y
0.00
Y
Y
0.00
Y
Y
0.00
Y
Y
0.00
Y
Y
0.00
Y
Y
0.00
Y
Y
0.00
Y
Y
0.00
N
Y
0
6-127
Y
Y
0.00
6-128
FWD 1
N
Y
2
6-130
Y*
Y
0.0
Y*
Y
100.00
Y
Y
0.05
Y*
Y
100.00
N
Y
1
Y*
Y
0.0
Y*
Y
100.00
Y
Y
0.05
Y*
Y
100.00
N
Y
0
Y*
Y
0.0
Y*
Y
100.00
Y
Y
0.05
Y*
Y
100.00
N
Y
1
Y
Y
0
Y
Y
0.00
Y
Y
0.00