Code
Name
E10
Acceleration Time 2
E11
Deceleration Time 2
E12
Acceleration Time 3
E13
Deceleration Time 3
E14
Acceleration Time 4
E15
Deceleration Time 4
E16
Torque Limiter 2
E17
E20
Terminal [Y1] Function
E21
Terminal [Y2] Function
E22
Terminal [Y3] Function
E23
Terminal [Y4] Function
E24
Terminal [Y5A/C] Function
E27
Terminal [30A/B/C] Function
Available in the ROM version 1600 or later.
*10 Available at ROM version
2450
221 (1221): External PID control 3 ON command
222 (1222): Cancel external PID control 3
223 (1223): Switch normal/inverse operation
under external PID control 3
224 (1224): Reset external PID3 integral and
differential components
225 (1225): Hold external PID3 integral component
Setting the value in parentheses ( ) shown above assigns a
negative logic output to a terminal. (True if OFF.)
Setting the value of 1000s in parentheses ( ) shown above
assigns a negative logic input to a terminal.
0.00 to 3600.00 s
Note: Entering 0.00 cancels the acceleration time, requiring
external soft-start and -stop.
(Driving) OFF: Disable
20% to 150%: Torque limiter level
(Braking)
Selecting function code data assigns the corresponding function
to terminals [Y1] to [Y5A/C] and [30A/B/C] as listed below.
0 (1000):
Inverter running
1 (1001):
Frequency (speed) arrival signal
2 (1002):
Frequency (speed) detected
3 (1003):
Undervoltage detected (Inverter stopped)
5 (1005):
Inverter output limiting
6 (1006):
Auto-restarting after momentary power
failure
(Relay output)
7 (1007):
Motor overload early warning
10 (1010):
Inverter ready to run
11:
Switch motor drive source between
commercial power and inverter output
(For MC on commercial line)
12:
Switch motor drive source between
commercial power and inverter output
(For secondary side)
13:
Switch motor drive source between
commercial power and inverter output
(For primary side)
15 (1015):
Select AX terminal function
(For MC on primary side)
16 (1016):
Shifted to pattern operation stage
17 (1017):
Pattern operation cycle completed
18 (1018):
Pattern operation stage number
19 (1019):
Pattern operation stage number
20 (1020):
Pattern operation stage number
22 (1022):
Inverter output limiting with delay
25 (1025):
Cooling fan in operation
26 (1026):
Auto-resetting
27 (1027):
Universal DO
28 (1028):
Heat sink overheat early warning
30 (1030):
Lifetime alarm
31 (1031):
Frequency (speed) detected 2
33 (1033):
Reference loss detected
35 (1035):
Inverter output on
36 (1036):
Overload prevention control
37 (1037):
Current detected
38 (1038):
Current detected 2
42 (1042):
PID alarm
43 (1043):
Under PID control
44 (1044):
Motor stopped due to slow
flowrate under PID control
45 (1045):
Low output torque detected
52 (1052):
Running forward
53 (1053):
Running reverse
54 (1054):
In remote operation
55 (1055):
Run command entered
56 (1056):
Motor overheat detected by thermistor
59 (1059):
Terminal [C1] wire break
84 (1084):
Maintenance timer
87(1087):
Frequency arrival signal
95(1095):
Running in fire mode
98 (1098):
Light alarm
99 (1099):
Alarm output (for any alarm)
101(1101): EN terminal detection circuit error
102(1102): EN terminal OFF
or later.
Data setting range
(EPID3-ON)
(%/EPID3)
(EPID3-IVS)
(EPID3-RST)
(EPID3-HLD)
(RUN)
(FAR)
(FDT)
(RDY)
(SW88)
(SW52-2)
(SW52-1)
(STG1)
(STG2)
(STG4)
(IOL2)
(FAN)
(TRY)
(U-DO)
(LIFE)
(FDT2)
(REF OFF)
(RUN2)
(OLP)
(ID2) *10
(PID-ALM)
(PID-CTL)
(PID-STP)
(U-TL)
(FRUN)
(RRUN)
(RMT)
(AX2)
(THM)
(C1OFF)
(MNT)
(FARFDT)
(FMRUN)
(L-ALM)
(ALM)
(DECF)
(ENOFF)
6-6
Change
Data
Default
when
copying
setting
running
Y
Y
20.00
Y
Y
20.00
Y
Y
20.00
Y
Y
20.00
Y
Y
20.00
Y
Y
20.00
Y
Y
OFF
Y
Y
OFF
N
Y
0
N
Y
1
N
Y
2
N
Y
7
(LU)
(IOL)
N
Y
15
N
Y
99
(IPF)
(OL)
(AX)
(TU)
(TO)
(OH)
(ID)
Related
page
6-84
6-105
6-106