Three-Phase 575 V Class Series (Usa Models) - Fuji Electric FRENIC-HVAC User Manual

Frenic-hvac series
Hide thumbs Also See for FRENIC-HVAC:
Table of Contents

Advertisement

2.1.3

Three-phase 575 V class series (USA models)

(001 to 050 HP)
Item
Type
(FRN_ _ _AR1-5U) (*1)
Nominal
Three
AC575V
applied motor
phase
motor
[HP] (*2)
input
(Rated output)
Single
phase
input
Three
Rated capacity (kVA)
phase
(*3)
input
Rated current (A)
Single
Rated capacity (kVA)
phase
(*3)
input
Rated current (A)
Rated voltage (V) (*4)
Overload capability
Three
Main power supply
phase
(number of phases,
input
voltage, frequency)
Rated current (A)
(*5)
Required power
supply capacity
[kVA]
Main power supply
(number of phases,
voltage, frequency)
Single
phase
Rated current [A] (*5) -
input
Required power
supply capacity
[kVA]
Auxiliary control power
supply:
(number of phases, voltage,
frequency)
Auxiliary main power supply
(number of phases, voltage,
frequency) (*6)
Voltage, frequency variations Voltage: +10 to -15% (Interphase voltage unbalance : 2% or less) (*9), Frequency: +5 to -5%
Braking torque [%] (*7)
DC injection braking
EMC filter (IEC/EN 61800-3) (*8)
DC reactor (DCR) (*8)
Fundamental
Power factor
wave power factor
(at the rated
load)
Total power factor ≥ 0.90
Efficiency (at the rated load) (%)
Applicable (safety) standards
Enclosure
NEMA/UL 50
Cooling method
Weight / Mass
NEMA/UL Type 1
[lbs]
NEMA/UL Type 12
UL open type
Site location
UL open type /
NEMA/
Ambient
UL Type 1
temperature
NEMA/
UL Type 12
Relative humidity
Atmosphere
Altitude
Atmospheric pressure
Vibration
001
002
003
005
1
2
3
5
-
1/2
3/4
1.5
1.6
2.7
3.8
6.1
1.7
2.8
3.9
6.2
-
0.9
1.4
2.3
-
1.0
1.5
2.4
Three-phase, 575 to 600 V (with AVR function)
110%-1 min (Overload interval: Compliant with IEC 61800-2)
Three-phase, 575 to 600 V, 50/60 Hz
1.2
2.1
3.0
5.2
1.2
2.1
3.0
5.2
Single-phase, 575 to 600 V, 50/60 Hz
2.1
3.0
5.2
-
1.3
1.8
3.0
Single-phase, 575 to 600 V, 50/60 Hz
-
20
Braking start frequency: 0.0 to 60.0 Hz; Braking time: 0.0 to 30.0 s; Braking operation level: 0 to 60%
EMC standards compliance : Category C3 (emission) / 2nd Env. (Immunity)
Built-in (IEC/EN 61000-3-2(*10), IEC/EN 61000-3-12)
> 0.98
95
96
97
97
UL 508C, C22.2 No. 14, IEC/EN 61800-5-1
NEMA/UL Type 1, NEMA/UL Type 12(*11)
Fan cooling
22
22
22
22
22
22
22
22
-
Indoors
14 to 122°F
14 to 104°F
5 to 95% (No condensation)
The inverter must not be exposed to dust, direct sunlight, corrosive gases, flammable gases, oil mist, vapor or
water drops. Pollution degree 2 (IEC/EN 60664-1) (*12)
The atmosphere can contain a small amount of salt. (0.01 mg/cm
The inverter must not be subjected to sudden changes in temperature that will cause condensation to form.
3,300 ft max. (*13)
86 to 106 kPa
3mm
2 to less than 9 Hz
2
10 m/s
9 to less than 200 Hz
Specifications
007
010
015
020
7.5
10
15
20
2
3
5
5
9.2
11
16
21
9.3
12
17
22
3.5
4.5
6.5
8.4
3.6
4.6
6.6
8.5
7.2
9.7
14.4
19.5
7.2
10
15
20
7.2
9.7
14.4
19.5
4.2
5.6
8.3
12
97
97
97
97
22
22
40
40
22
22
40
40
2
or less per year)
2-6
025
030
040
050
25
30
40
50
7.5
10
10
15
26
31
40
51
27
32
41
52
10
12
15
20
10.5
12.4
15.9
20.2
24.0
28.6
38.8
48.3
24
29
39
49
24.0
28.6
38.8
48.3
14
17
23
28
10 to 15
98
98
98
98
40
40
51
51
40
40
51
51