Fuji Electric FRENIC-HVAC User Manual page 37

Frenic-hvac series
Hide thumbs Also See for FRENIC-HVAC:
Table of Contents

Advertisement

(100 to 1000 HP)
Item
Type
(FRN_ _ _AR1-4U) (*1)
Nominal
Three
AC460V
applied
phase
motor
motor (HP)
input
(*2)
Single
(Rated
phase
output)
input
Three
Rated capacity (kVA)
phase
(*3)
input
Rated current (A)
Single
Rated capacity (kVA)
phase
(*3)
input
Rated current (A)
Rated voltage (V) (*4)
Overload capability
Three
Main power supply
phase
(number of phases,
input
voltage, frequency)
Rated current (A) (*5)
Required power
supply capacity [kVA]
Main power supply
(number of phases,
Single
voltage, frequency)
phase
Rated current [A] (*5)
input
Required power
supply capacity [kVA]
Auxiliary control power supply:
(number of phases, voltage,
frequency)
Auxiliary main power supply
(number of phases, voltage,
frequency) (*6)
Voltage, frequency variations Voltage: +10 to -15% (Interphase voltage unbalance : 2% or less) (*9), Frequency: +5 to -5%
Braking torque [%] (*7)
DC injection braking
EMC filter (IEC/EN 61800-3) (*8)
DC reactor (DCR) (*8)
Fundamental wave
Power factor
power factor
(at the rated
load)
Total power factor
Efficiency (at the rated load) (%)
Safety standard compliance
NEMA/UL 50
Enclosure
Cooling method
Weight /
NEMA/UL Type 1
Mass [lbs]
NEMA/UL Type 12
UL open type
Site location
UL open type /
NEMA/
Ambient
UL Type 1
temperature
NEMA/
UL Type 12
Relative humidity
Atmosphere
Altitude
Atmospheric pressure
Vibration
100
125
150
200
100
125
150
200
40
50
60
75
119
140
167
201
150
176
210
253
46
54
65
78
58.5
68.6
81.9
98.6
Three-phase, 380 to 480 V (with AVR function)
110%-1 min (Overload interval: Compliant with IEC 61800-2)
Three-phase, 380 to 440 V, 50 Hz
Three-phase, 380 to 480 V, 60 Hz
119
141
175
207
95
113
140
165
Single-phase, 380 to 440 V, 50 Hz
Single-phase, 380 to 480 V, 60 Hz
119
141
175
207
55
65
81
96
Single-phase, 380 to 480 V, 50/60 Hz
Single-phase, 380 to 440 V, 50 Hz
Single-phase, 380 to 480 V, 60 Hz
10 to 15
Braking start frequency: 0.0 to 60.0 Hz; Braking time: 0.0 to 30.0 s; Braking operation level: 0 to 60%
C2/2nd
EMC standards compliance: Category C3 (emission) / 2nd Env. (Immunity)
Built-in (IEC/EN
61000-3-2
Standard accessory (IEC/EN 61000-3-12)
(*10),
IEC/EN
61000-3-12)
> 0.98
≥ 0.90
98
98
98
98
UL 508C, C22.2 No. 14 , IEC/EN 61800-5-1, SEMI F47-0706
NEMA/UL Type
1, NEMA/UL
UL open type
Type 12(*11)
Fan cooling
154
154
154
154
-
137
141
Indoors
14 to 122°F
14 to 122°F
5 to 95% (No condensation)
The inverter must not be exposed to dust, direct sunlight, corrosive gases, flammable gases, oil mist, vapor or
water drops. Pollution degree 2 (IEC/EN 60664-1) (*12)
The atmosphere can contain a small amount of salt. (0.01 mg/cm
The inverter must not be subjected to sudden changes in temperature that will cause condensation to form.
3,300 ft max. (*13)
86 to 106 kPa
100 to 125 HP or less
3mm
2 to less than 9 Hz
2
10 m/s
9 to less than 200 Hz
Specifications
250
300
350
450
250
300
350
450
75
100
125
150
242
300
330
414
304
377
415
520
94
117
128
160
118
147
161
202
249
311
340
435
199
248
271
347
249
311
340
435
115
144
157
201
98
98
98
98
-
207
216
284
309
2
or less per year)
150 to 1000 HP
3mm
2 to less than 9 Hz
2
2m/s
9 to less than 55 Hz
2
1m/s
55 to less than 200 Hz
2-4
500
600
800
900
1000
500
600
800
900
1000
200
200
300
350
517
589
764
932
1091
650
740
960
1170
1370
201
229
297
363
253
288
374
456
547
614
767
970
1093
436
490
612
773
547
614
767
970
1093
252
282
353
447
98
98
98
98
540
540
728
1168
1168
450
425
534
871
503
98