Function (F31, F35)
F31 or F35 specifies what is output to analog output terminal [FM1] or [FM2], respectively.
Data for
[FM1] output
F31, F35
Output frequency 1
(before slip
0
compensation)
Output frequency 2
(after slip
1
compensation)
Output current
2
Output voltage
3
Output torque
4
Load factor
5
Input power
6
PID feedback
7
amount
DC link bus voltage
9
Universal AO
10
Motor output
13
Calibration (+)
14
PID command (SV)
15
PID output (MV)
16
Inverter heat sink
18
temperature
Reference
20
frequency
PID feedback
50
amount 1 (PV1)
PID command 1
51
(SV1)
PID deviation 1
52
(ERR1)
PID final deviation
53
(ERR)
PID feedback
54
amount 2 (PV2)
PID command 2
55
(SV2)
PID deviation 2
56
(ERR2)
External PID
feedback amount 1
60
(EPID1-PV)
External PID
command 1
61
(EPID1-SV)
Function
(Monitor the following)
Output frequency of the inverter
(Equivalent to the motor
synchronous speed)
Output frequency of the inverter
Output current (RMS) of the inverter
Output voltage (RMS) of the
inverter
Motor shaft torque
Load factor
(Equivalent to the indication of the
load meter)
Input power of the inverter
Feedback amount under PID control 100% of the feedback amount
DC link bus voltage of the inverter
Command via communications link
(
Refer to the RS-485
Communication User's Manual.)
Motor output (kW)
Full scale output for the meter
calibration
Command value under PID control
Output level of the PID processor
under PID control (Frequency
command)
Heat sink temperature inside the
inverter unit
Frequency command input to the
inverter
Feedback amount under PID control 100% of the feedback amount
Command value 1 under PID control 100% of the feedback amount
Deviation 1 under PID control
(SV1 - PV1) (*1)
Final deviation under PID control
(ERR1, ERR2) (*1)
Feedback amount 2 under PID
control
Command value 2 under PID control 100% of the feedback amount
Deviation 2 (SV2-PV2) under PID
control (*1)
Feedback amount under external
PID control 1
Command value under external PID
control 1
6-72
Meter scale
(Full scale at 100%)
Maximum frequency (F03)
Maximum frequency (F03)
Twice the inverter rated
current
500 V
Twice the rated motor torque
Twice the rated motor load
Twice the rated output of the
inverter
1000 V
20000 as 100%
Twice the rated motor output
This always outputs the
full-scale (100%).
100% of the feedback amount
Maximum frequency (F03)
0 to 200°C (32 to 392°F)
Maximum frequency (F03)
100% of the feedback amount
100% of the feedback amount
100% of the feedback amount
100% of the feedback amount
100% of the feedback amount
100% of the feedback amount