Code
Name
U36
Customizable Logic: Step 8
(Control function)
U37
U38
U39
U40
U41
Customizable Logic: Step 9
(Control function)
U42
U43
U44
U45
U46
Customizable Logic: Step 10
(Control function)
U47
U48
U49
U50
U51
Customizable Logic: Step 11
(Control function)
U52
U53
U54
U55
U56
Customizable Logic: Step 12
(Control function)
U57
U58
U59
U60
U61
Customizable Logic: Step 13
(Control function)
U62
U63
U64
U65
U66
Customizable Logic: Step 14
(Control function)
U67
U68
U69
U70
U71
Customizable Logic Output Signal 1
(Output selection)
U72
Customizable Logic Output Signal 2
U73
Customizable Logic Output Signal 3
U74
Customizable Logic Output Signal 4
U75
Customizable Logic Output Signal 5
U76
Customizable Logic Output Signal 6
U77
Customizable Logic Output Signal 7
U81
Customizable Logic Output Signal 1
(Function selection)
U82
Customizable Logic Output Signal 2
U83
Customizable Logic Output Signal 3
U84
Customizable Logic Output Signal 4
U85
Customizable Logic Output Signal 5
U86
Customizable Logic Output Signal 6
U87
Customizable Logic Output Signal 7
See U01.
(Input 1) See U02.
(Input 2) See U02.
(Function 1) -9990.00 to 0.00 to 9990.00
(Function 2) -9990.00 to 0.00 to 9990.00
See U01.
(Input 1) See U02.
(Input 2) See U02.
(Function 1) -9990.00 to 0.00 to 9990.00
(Function 2) -9990.00 to 0.00 to 9990.00
See U01.
(Input 1) See U02.
(Input 2) See U02.
(Function 1) -9990.00 to 0.00 to 9990.00
(Function 2) -9990.00 to 0.00 to 9990.00
See U01.
(Input 1) See U02.
(Input 2) See U02.
(Function 1) -9990.00 to 0.00 to 9990.00
(Function 2) -9990.00 to 0.00 to 9990.00
See U01.
(Input 1) See U02.
(Input 2) See U02.
(Function 1) -9990.00 to 0.00 to 9990.00
(Function 2) -9990.00 to 0.00 to 9990.00
See U01.
(Input 1) See U02.
(Input 2) See U02.
(Function 1) -9990.00 to 0.00 to 9990.00
(Function 2) -9990.00 to 0.00 to 9990.00
See U01.
(Input 1) See U02.
(Input 2) See U02.
(Function 1) -9990.00 to 0.00 to 9990.00
(Function 2) -9990.00 to 0.00 to 9990.00
0: Disable
1: Output of step 1
2: Output of step 2
3: Output of step 3
4: Output of step 4
5: Output of step 5
6: Output of step 6
7: Output of step 7
8: Output of step 8
9: Output of step 9
10: Output of step 10
11: Output of step 11
12: Output of step 12
13: Output of step 13
14: Output of step 14
0 (1000):
Select multistep frequency (0 to 1 step)
1 (1001):
Select multistep frequency (0 to 3 steps)
2 (1002):
Select multistep frequency (0 to 7 steps)
3 (1003):
Select multistep frequency (0 to 15 steps)
4 (1004):
Select ACC/DEC time (2 steps)
5 (1005):
Select ACC/DEC time (4 steps)
6 (1006):
Enable 3-wire operation
7 (1007):
Coast to a stop
8 (1008):
Reset alarm
9 (1009):
Enable external alarm trip
(9 = Active OFF, 1009 = Active ON)
11 (1011): Select frequency command 2/1
13:
Enable DC braking
14 (1014): Select torque limiter level 2/1
15:
Switch to commercial power (50 Hz)
16:
Switch to commercial power (60 Hz)
Data setting range
(SO01)
(SO02)
(SO03)
(SO04)
(SO05)
(SO06)
(SO07)
(SO08)
(SO09)
(SO10)
(SO11)
(SO12)
(SO13)
(SO14)
(SS1)
(SS2)
(SS4)
(SS8)
(RT1)
(RT2)
(HLD)
(RST)
(THR)
(Hz2/Hz1)
(DCBRK)
(TL2/TL1)
(SW50)
(SW60)
6-28
Change
Data
Default
when
copying
setting
running
N
Y
0
N
Y
0
N
Y
0
N
Y
0.00
N
Y
0.00
N
Y
0
N
Y
0
N
Y
0
N
Y
0.00
N
Y
0.00
N
Y
0
N
Y
0
N
Y
0
N
Y
0.00
N
Y
0.00
N
Y
0
N
Y
0
N
Y
0
N
Y
0.00
N
Y
0.00
N
Y
0
N
Y
0
N
Y
0
N
Y
0.00
N
Y
0.00
N
Y
0
N
Y
0
N
Y
0
N
Y
0.00
N
Y
0.00
N
Y
0
N
Y
0
N
Y
0
N
Y
0.00
N
Y
0.00
N
Y
0
N
Y
0
N
Y
0
N
Y
0
N
Y
0
N
Y
0
N
Y
0
N
Y
100
N
Y
100
N
Y
100
N
Y
100
N
Y
100
N
Y
100
(BX)
N
Y
100
Related
page
6-249

Hide quick links:

Advertisement

Table of Contents
loading