Fuji Electric FRENIC-HVAC User Manual page 334

Frenic-hvac series
Hide thumbs Also See for FRENIC-HVAC:
Table of Contents

Advertisement

Code
Name
J652 External PID Control 3
(Remote command selection)
J653
(Feedback selection) 51: External PID feedback value 1
J655
J656
(Maximum scale) -999.00 to 0.00 to 9990.00
J657
(Minimum scale) -999.00 to 0.00 to 9990.00
J660
J661
J662
D (Differential time) 0.00 to 600.00 s
J663
(Feedback filter) 0.0 to 900.0 s
J664
(Anti-reset wind-up) OFF: Disable
J665
(ON/OFF control hysteresis width) 0.00 to 9990.00
J666
(Proportional operation output convergent
J667
(Proportion cycle) 1 to 150 s
J668
(Upper limit of PID process output) -10 to +110%
J669
(Lower limit of PID process output) -10 to +110%
J670
(Upper and lower limits) 0: Limit PID output with J618,J619
J671
(Alarm output selection) 0: Absolute-value alarm (PV)
J672
(Upper level alarm (AH)) OFF: Disable
J674
(Lower level alarm (AL)) OFF: Disable
J677
(Feedback error detection mode) 0: Disable (Turns ON output signals (EPV3-ERR) and continues
J679
(Feedback error upper-limit) Auto: 105% equivalent
J680
(Feedback error lower-limit) Auto: -5% equivalent
J681
(Feedback error detection time) 0.0 to 300.0 s
J690
(Manual commands) 0: Keypad ( /
*6 The upper and lower level values are restricted by the maximum and minimum scales.
0: Keypad ( /
key)
3: UP/DOWN
4: Command via communications link (Use function code S32)
51: External PID process command 1 (Analog input: Terminals
[12], [C1] and [V2])
52: External PID process command 2 (Analog input: Terminals
[12], [C1] and [V2])
53: External PID process command 3 (Analog input: Terminals
[12], [C1] and [V2])
111: Apply external PID control 1 commands
112: Apply external PID control 2 commands
52: External PID feedback value 2
53: External PID feedback value 3
(Display unit) See J605.
P (Gain) ON/OFF: ON/OFF control
0.000 to 30.000 times
I (Integral time) 0.0 to 3600.0 s
0.00 to 9990.00
*6
*6
0 to 150%
value)
1: 110%, -10% of PID output with J618 exceeded or less than
J619
1: Absolute-value alarm (PV) (with Hold)
2: Absolute-value alarm (PV) (with Latch)
3: Absolute-value alarm (PV) (with Hold and Latch)
4: Deviation alarm
5: Deviation alarm (PV) (with Hold)
6: Deviation alarm (PV) (with Latch)
7: Deviation alarm (PV) (with Hold and Latch
8: Absolute-value alarm (SV)
9: Absolute-value alarm (SV) (with Hold)
10: Absolute-value alarm (SV) (with Latch)
11: Absolute-value alarm (SV) (with Hold and Latch)
12: Absolute-value alarm (MV)
13: Absolute-value alarm (MV) (with Hold)
14: Absolute-value alarm (MV) (with Latch)
15: Absolute-value alarm (MV) (with Hold and Latch)
-999.00 to 0.00 to 9990.00
-999.00 to 0.00 to 9990.00
operation.)
1: Enable (Free run stop (PVC trip))
2: Enable (Deceleration and stop (PVC trip))
-999.00 to 0.00 to 9990.00
-999.00 to 0.00 to 9990.00
key)
8: Keypad ( /
key) (Balanceless-bumpless)
51: External PID manual command 1 (Analog input: Terminals
[12], [C1] and [V2])
52: External PID manual command 2 (Analog input: Terminals
[12], [C1] and [V2])
53: External PID manual command 3 (Analog input: Terminals
[12], [C1] and [V2])
111: Apply external PID control 1 manual commands
112: Apply external PID control 2 manual commands
Data setting range
*6
*6
*6
*6
6-24
Change
Data
Default
Related
when
copying
setting
page
running
N
Y
0
6-247
N
Y
53
N
Y
0
N
Y
100
N
Y
0.00
Y
Y
0.100
Y
Y
0.0
Y
Y
0.00
Y
Y
0.5
Y
Y
OFF
Y
Y
0.00
Y
Y
0
Y
Y
30
6-248
Y
Y
100
Y
Y
0
Y
Y
0
Y
Y
0
Y
Y
OFF
Y
Y
OFF
Y
Y
0
Y
Y
Auto
Y
Y
Auto
Y
Y
0.1
N
Y
0