1.
If n is not between 1–256, the instruction is not executed, SM0 is ON, and the error code in SR0 is 16#200B.
2.
If the devices specified by S+n-1 and D+n-1 exceed the range of possible devices, the instruction is not executed,
SM0 is ON, and the error code in SR0 is 16#2003.
3.
If the data in S is not a binary-coded decimal, the instruction is not executed, and the error code in SR0 is
16#200D. The binary-coded decimal value is represented by the hexadecimal number, but one of digits is not
between 0–9.
4.
If S–S+n-1 overlap D–D+n-1, the instruction is not executed, SM0 is ON, and the error code in SR0 is 16#200C.