Display Transceiver - HP E4510-48G Command Reference Manual

4510g series
Table of Contents

Advertisement

Table 4-9 display transceiver diagnosis command output description
transceiver diagnostic information
Current diagnostic parameters
Temp.(°C)
Voltage(V)
Bias(mA)
RX power(dBM)
TX power(dBM)

display transceiver

Syntax
display transceiver interface [ interface-type interface-number ]
View
Any view
Default Level
2: System level
Parameters
interface [ interface-type interface-number ]: Displays main parameters of the pluggable transceiver
plugged in the specified interface. interface-type interface-number represents interface type and
interface number. If it is not specified, the command displays main parameters of the pluggable
transceiver(s) in all the interfaces.
Description
Use the display transceiver command to display main parameters of a single or all pluggable
transceivers.
Examples
# Display main parameters of the pluggable transceiver plugged in interface GigabitEthernet1/0/3.
<Sysname> display transceiver interface gigabitethernet1/0/3
GigabitEthernet1/0/3 transceiver information:
Transceiver Type
Connector Type
Wavelength(nm)
Transfer Distance(m)
Field
: 1000_BASE_SX_SFP
: LC
: 850
: 550(50um),270(62.5um)
Description
Digital diagnosis information of the transceiver plugged in
the interface
Current diagnostic parameters
Digital diagnosis parameter-temperature, in °C, with the
precision to 1°C.
Digital diagnosis parameter-voltage, in V, with the
precision to 0.01 V.
Digital diagnosis parameter-bias current, in mA, with the
precision to 0.01 mA.
Digital diagnosis parameter-RX power, in dBM, with the
precision to 0.01 dBM.
Digital diagnosis parameter-TX power, in dBM, with the
precision to 0.01 dBM.
4-22

Advertisement

Table of Contents
loading

Table of Contents