interval sampling-interval: Sampling period, in the range 5 to 3600 seconds.
owner text: Owner of the entry, a string of 1 to 127 characters. It is case sensitive and space is
supported.
Description
Use the rmon history command to create an entry in the RMON history control table.
Use the undo rmon history command to remove a specified entry from the RMON history control
table.
After an entry is created, the system periodically samples the number of packets received/sent on the
current interface, and saves the statistics as an instance under the leaf node of the etherHistoryEntry
table. The maximum number of history entries can be saved in the table is specified by buckets
number. If the number of the entries in the table has reached the maximum number, the system will
delete the earliest entry to save the latest one. The statistics include total number of received packets
on the current interface, total number of broadcast packets, and total number of multicast packets in a
sampling period,
When you create an entry in the history table, if the specified history table size exceeds that supported
by the device, the entry will be created. However, the validated value of the history table size
corresponding to the entry is that supported by the device. You can use the display rmon history
command to view the configuration result.
When you create an entry, if the value of the specified sampling interval (interval
sampling-interval) is identical to that of the existing history entry, the system considers their
configurations are the same and the creation fails.
You can create up to 100 alarm entries.
Related commands: display rmon history.
Examples
# Create RMON history control entry 1 for interface GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface GigabitEthernet 1/0/1
[Sysname-GigabitEthernet1/0/1] rmon history 1 buckets 10 interval 5 owner user1

rmon prialarm

Syntax
rmon prialarm entry-number prialarm-formula prialarm-des sampling-interval { absolute |
changeratio
|
threshold-value2 event-entry2 entrytype { forever | cycle cycle-period } [ owner text ]
undo rmon prialarm entry-number
delta
}
rising-threshold
threshold-value1
12-14
event-entry1
falling-threshold