Display Transceiver Alarm - HP FlexFabric 7900 Series Command Reference Manual

Hide thumbs Also See for FlexFabric 7900 Series:
Table of Contents

Advertisement

Examples
# Display system working mode information.
<Sysname> display system-working-mode
The current system working mode is standard.
The next system working mode is standard.

display transceiver alarm

Use display transceiver alarm to display transceiver alarms.
Syntax
display transceiver alarm interface [ interface-type interface-number ]
Views
Any view
Predefined user roles
network-admin
network-operator
mdc-admin
mdc-operator
Parameters
interface [ interface-type interface-number ]: Specifies an interface by its type and number. If no
interface is specified, this command displays the alarms present on every transceiver module.
Usage guidelines
Table 37
shows the common transceiver alarm components. If no error occurs, None is displayed.
Table 37 Common transceiver alarm components
Field or field component
REFCLK
RX ...
TX ...
TX bias high
TX bias low
Temp high
Temp low
Transceiver type and port configuration
mismatch
Examples
# Display the alarms present on the transceiver module in interface FortyGigE 1/0/1.
<Sysname> display transceiver alarm interface fortygige 1/0/1
FortyGigE1/0/1 transceiver current alarm information:
RX loss of signal(channel 1)
RX loss of signal(channel 2)
RX loss of signal(channel 3)
Remarks
Reference clock.
Received ...
Transmitted ...
The transmitted bias current is high.
The transmitted bias current is low.
The temperature is high.
The temperature is low.
The type of the transceiver module does not match the
port configuration.
226