Info-Center Enable - HP E4510-48G Command Reference Manual

4510g series
Table of Contents

Advertisement

Parameters
channel-number: Specifies a channel number, in the range 0 to 9.
channel-name: Specifies a channel name, which could be a default name or a self-defined name. The
user needs to specify a channel name first before using it as a self-defined channel name. For more
information, refer to the info-center channel name command.
Description
Use the info-center console channel command to specify the channel to output system information
to the console.
Use the undo info-center console channel command to restore the default output channel to the
console.
By default, output of information to the console is enabled with channel 0 as the default channel
(known as console).
Note that the info-center console channel command takes effect only after the information center is
enabled first with the info-center enable command.
Examples
# Set channel 0 to output system information to the console.
<Sysname> system-view
[Sysname] info-center console channel 0

info-center enable

Syntax
info-center enable
undo info-center enable
View
System view
Default Level
2: System level
Parameters
None
Description
Use the info-center enable command to enable information center.
Use the undo info-center enable command to disable the information center.
The system outputs information to the log host or the console only after the information center is
enabled first.
By default, the information center is enabled.
Examples
# Enable the information center.
16-10