1-580 Trouble locating and clearing procedures (continued)

TOPS MPX Token Ring LAN troubleshooting

Error codes
Ring Diagnostic output error codes (166nn) (Sheet 1 of 2)
Error Code
16689
16690
16691
297-8021-544 Standard 14.02 May 2001
Meaning
Microcode download failure
The adapter microcode download
fails.
Adapter card test failure
The diagnostics detect a failure during
initialization of the adapter.
Open phase test failure
Action
Make sure the adapter is firmly seated
in the adapter slot.
Make sure the adapter microcode is
loaded to the correct disk or diskette.
Run the diagnostics again. If the
failure continues to occur, follow the
remove and replace procedures for
the TOPS MPX position. This
procedure is located in the common
procedures section of this manual.
Make sure the adapter is firmly seated
in the adapter slot.
Check the established configuration.
If necessary run the automatic
configuration procedure.
Run the diagnostics again. If the
failure continues to occur, follow the
remove and replace procedures for
the TOPS MPX position. These
procedures are located in the common
procedures section of this manual.
Replace the adapter cable with a
spare working cable until the problem
is fixed.
Run the diagnostics again. If the
failure continues to occur, follow the
remove and replace procedures for
the TOPS MPX position. These
procedures are in the common
procedures section of this manual.
If the failure does not occur again, the
adapter cable is defective. Replace
the damaged cable.

Advertisement