Nortel North American DMS-100 Instruction Manual page 376

Table of Contents

Advertisement

57
58
59
DMS-100 Family NA100 Trouble Locating and Clearing Procedures Volume 2 of 2 LET0015 and up
Trouble locating and clearing procedures (continued)
Running a C7BERT for high-speed links
link_no
is the number of the link (0 to 15) on which the HSL C7BERT is running
number
is the number of reports per hour (1 to 12)
Example input:
>REPORT
1
ON
6
If the response is
Link nn: Report interval set at:
nn times per hour
anything else
Determine if the report interval is correct.
If the interval is
correct
not correct
To stop the HSL C7BERT, type
>STOP
link_no
and press the Enter key.
where
link_no
is the number of the link (0 to 15) on which the HSL C7BERT is running
Note: The STOP command overrides any preset stop time without
warning.
If the response is
Link 1: C7BERT stopped
anything else
Give the results to the personnel responsible for the next level of support.
Your next step depends on the instructions received from your next level of
support.
If
the far-end DS-1 loopback is es-
tablished
the local loopback is established step 60
Do
step 57
step 78
Do
step 42
step 55
Do
step 59
step 78
Do
step 61
1-361
(continued)

Advertisement

Table of Contents
loading

Table of Contents